TO-6 surge protective device SPD 100KA
TO-6 surge protective device SPD 100KA:
Product Description
TO-B series surge protective device(in short:SPD,alias:surge protector,surge arrester)is suitable for TN-S,TN-C-S,TT,IT etc.power supply system of AC 50/60Hz.≤380V,and used at the equipotential connection,which protects the
electric network not shocked by the thunder and lightning,it's designed according to GB18802.1,IEC61643-1,it adopts 35mm standard rail,there is a failure release mounted on the module of surge protective device,
When the SPD fails in breakdown for over-heat and over-current,
the failure release will help electric device separate from the power system and give the indication signal,green means
normal,red means abnormal,Kevin wiring mode,remote signaling output interface.it's also could be replaced for the
module when has operating voltage.
Application Scope and Installation Position
TO-B-150,TO-B-120,TO-B-100 series surge protective devices are suitable for B grade lightning-proof,
used at the quipotential connection of LPZOA or LPZOB and LPZ1 zone,which protects the electrle network not
shocked by the thunder.TO6-80,TO6-60 series surge protective devices are usually
installed in low voltage main distribution box connected to the incoming end of the buildings.
Notice:When you order our goods,please write the model and quantity carefully.For example:TO-B-150/4-385,8PCS
Model | TO-B 200 | TO-B 150 | TO-B 120 | TO-B 100 | TO-B 80 | TO6 60 | ||||
Technical Parameters | ||||||||||
Rated Operating Voltage Un(V~) | 220V/380V | |||||||||
Maximum Continuous Operating Voltage Uc(V~) | 385/420V | |||||||||
Voltage Protection Level Up(V~)KV | ≤4.0 | ≤3.2 | ≤3.0 | ≤2.8 | ≤2.4 | ≤2.2 | ||||
Maximum Discharge Current Imax(8/20us)KA | 150 | 150 | 120 | 100 | 80 | 60 | ||||
Nominal Discharge Current In(8/20us)KA | 200 | 100 | 80 | 60 | 40 | 30 | ||||
Response Times | <2.5 | |||||||||
The Cross Section of L/N Line | 25,35 | 16,25 | 16,25 | 16,25 | 16,25 | |||||
The Cross Section of PE line (mm²) | 35 | 25,35 | 25,35 | 25,35 | 16,25 | |||||
Fuse or Switch(A) | 63A,125A | 63A | 63A | 63A | 63A,32A | |||||
The Line Section of Communication and Alarm | ≤1.5 | |||||||||
Operating Environment°C | -40°C~+85°C | |||||||||
Relative Humidity(25°C) | ≤95% | |||||||||
Installation | Standard Rail 35mm | |||||||||
Material of Outer Covering | Fiber glass reinforced plastic |
TO-6 surge protective device SPD 100KA