- Voltage Meters[2]
- Current Meters[9]
- Locks[10]
- Lamp Poles[10]
- Ventilation Fans[9]
- Fans & Cooling[3]
- Switching Power Supply[10]
- Gasoline Generators[1]
- Diesel Generators[1]
- Electric Bicycle Motor[6]
- Other Generators[3]
- Relays[2]
- Timers[4]
- Circuit Breakers[5]
- Other Security & Protection Products[2]
- Lightning Rod[7]
- Solar Controllers[2]
- Lock Parts[2]
- Contact Person : Ms. Wu Marina
- Company Name : Yueqing Onlybo Instruments Co., Ltd.
- Tel : 0086-577-27878258
- Fax : 0086-577-27878258
- Address : Zhejiang,YUEQING,NO.152,XIXING ROAD,LIUSHI,YUEQING,ZHEJIANG,CHINA
- Country/Region : China
- Zip : 325604
S-100-48 dc power supply switching
S-100-48 dc power supply switching,DC power supply switching,switching adapter,notebook power adapter
Features:
105°C output capacitor
With short-circuit and overload protection
AC Input Power
100% full-load burn-in test
High efficiency&Low Operation temperture
Installed with EMI filter,minimum wave
Model Performance | S-100-3 | S-100-5 | S-100-7-5 | S-100-12 | S-100-15 | S-100-24 | S-100-27 | S-100-48 |
DC Output Volta | 3V | 5V | 7.5V | 12V | 15V | 24V | 27V | 48V |
Output voltage tolerance(Note 2) | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
Rated output current | 20A | 20A | 13.6A | 8.5A | 6.7A | 4.5A | 3.7A | 2A |
Output current range | 0-20A | 0-20A | 0-13.6A | 0-8.5A | 0-6.7A | 0-4.5A | 0-3.7A | 0-2A |
Ripple and noise(Note 3) | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Inlet stability(Note 4) | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
Load stability(Note 5) | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
DC output power | 60W | 100W | 102W | 102W | 100.5W | 108W | 99.9W | 96W |
Efficiency | 70% | 78% | 80% | 81% | 81% | 84% | 84% | 84% |
DC voltage adjustable range | 2.85-3.3V | 4.75-5.5V | 6.75-8.25V | 10.8-13.2V | 13.5-16.5V | 21.6-26.4V | 26-32V | 43.2-52.8V |
Input voltage range | 85~132VAC/180~264VAC choose by switch 47~63Hz;255-370VDC | |||||||
Input current | 2.4A/115V 1.2A/230V | |||||||
Surge Current | Cold Start current 30A/115V 60A/230V | |||||||
Leakage Current | <1mA/240VAC | |||||||
Overload protection | 105%~150% type:cut off output reset::automatic recovery | |||||||
over-voltage protection | …… | |||||||
High temperature protection | …… | |||||||
temperature coefficient | ±0.03%°C(0~50°C) | |||||||
Start-up,upper,rentention time | 200ms,100ms,30ms | |||||||
shock resistance | 10~500Hz,2G 10min./1circle,time60min,axes | |||||||
Withstand | Input to Output Isolation:1.5KVAC,input &shell:1.5KVAC,output &shell:0.5KVAC | |||||||
Insulation Resistance | Input to Output Isolation ,Input and out shell,output and out shell:500VAC/100M Ohms | |||||||
work Temperature/ humidity | -10°C~+60°C,20%~90%RH | |||||||
Storage Temperature,temperature | -20°C~+85°C,10%~95RH | |||||||
Outline dimension | 199*98*38mm CASE:902 | |||||||
Weight | 0.66Kgs | |||||||
Safety standards | Satisfy the requires of UL1012 | |||||||
EMC Standard | Satisfy FCC PART15J CONDUCTION CLASS B | |||||||
Note: 1.The above parameters test conditions: 230VAC input, rated load, 25 °C 70% RH. Humidity. 2.Tolerance: includes set up tolerance, line stability and load stability (Note 5). 3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uF capacitor circuit. 4.The incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage. 5.Load stability test: the load from 0% to 100%. |
S-100-48 dc power supply switching