1. 5V/12V/24V output voltage; 2. can special make all kinds of data; 3. CE certificate; 4. good quality fast delivery.

Power supply S-15-12

Model

Performance

S-15-5

S-15-12

S-15-24

DC output voltage

5V

12V

24V

Output voltage tolerance(Note 2)

±2%

±1%

±1%

Rated output current

3A

1.3A

0.7A

Output current range

0-3A

0-1.3A

0-0.7A

Ripple and noise(Note 3)

50mVp-p

50mVp-p

100mVp-p

Inlet stability(Note 4)

±0.5%

±0.5%

±0.5%

Load stability(Note 5)

±1%

±0.5%

±0.5%

DC output power

15W

15.6W

16.8W

Efficiency

65%

68%

72%

DC voltage adjustable range

±10,-5%

±10%

±10%

Input voltage range

85~132VAC/170~264VAC selected by switch 47~63Hz240~370VDC 

Input current

0.5A/115V 0.25A/230V

Surge Current

Cold-start current 15A/115V 30A/230V

Leakage Current

<0.5mA/240VAC

Overload protection

105%~150%type:pulsing hiccup shutdown Reset:auto recovery 

over-voltage protection

……

High temperature protection

……

temperature coefficient

±0.02%°C(0~50°C)

Start-up,rise,hold up time

200ms,100ms,30ms

shock resistance

10~500Hz,2G 10min./1circle,Period for 60min.,Each axes 

Withstand voltage

Input and Output internal:1.5KvAC,input and enclosure:1.5KvAC,

output and enclosure:0.5KvAC

Insulation Resistance

Input and Output internal: input and enclosure,output and enclosure:500VDC/

100M/Ohms

work temperature/humidity   

-10°C~+60°C(Refer to output derating curve),20%~90%RH

storage temperature /humidity

-20°C~+85°C,10%~95RH

Outline dimension

99*97*35mm CASE:905

weight

0.3Kgs

Safety standards

Satisfy the requires of UL1012

EMC Standards

Satisfy the clause CLASS B of  FCC PART15J

Note: 

1.The above parameters test conditions: 230VAC input, rated load, 25 °C 70% RH. 

  Humidity. 

2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).

3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uF 

  capacitor circuit. 

4.The incoming line voltage stability test: the minimum full load voltage of the 

  incoming line to the highest voltage. 

5.Load stability test: the load from 0% to 100%.